Testing Capabilities
Visual Inspection
- Performed to both SAE AS5553 and MIL-STD-883 Method 2009.9
- Component Condition
- Part Markings
- Evidence of a Secondary Coating
- Lead Conditions
- Dimensions
- Surface Quality
Full Electrical Testing
- AC/DC function test at temperature including up-screening of all devices.
- Active components
- Passive components
- Discrete components
X-Ray
- Non-destructive testing performed to both AS5553 and MIL-STD-883 2012.7
- Verify bond wire connections
- Die size comparisons
- ESD damage
X-Ray Florescence Spectroscopy (XRF)
- Non-destructive testing
- Can provide list of substances found for compliance with the EU Restriction of Hazardous Substances Directive (RoHS)